I.B.N Steam Nail Gel Removal Machine, ISGR-01 - Safety Notice

product recall nail gel

Risk

Electric shock

Models affected

Brand: I.B.N
Model: ISGR-01
Barcode: X000ZBJI5P

Details

A black and white nail gel removal machine with a black UK plug.

The product presents a high risk as during testing the insulation between the input and output circuits broke down when a 2.92kV test voltage was applied to the circuits. If the product were to fail during use, this could cause the metal parts of the product to become live and give the user an electric shock. The instructions were considered to be inadequate as they did not contain sufficient information to ensure the correct and safe use of the equipment. Some of the required documentation and markings were not present.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

Seesil Cordless Impact Wrench, WH710 - Safety Notice

impact wrench safety notice

Risk

Fire and electric shock.

Models affected

Brand: Seesil
Model: WH710
Charger model: HC 1610-2100750
Barcode: X001PUXY9B
SKU: CP3B0083UK-59HGQ
Other Amazon identifiers: FBA15HKXCH2LU000071

Details

A black and dark green/turquoise impact wrench with power supply and lithium battery. The product is supplied sealed in a hard carry case.

The product presents a risk of fire and electric shock as the plug, cable and fuse are counterfeit. There was no approval marking or ballast present in the fuse and the transformer was of poor build quality as it did not meet the meet the creepage and clearance requirements. Some of the required documentation and markings were not present.

The product does not meet the requirements of the Supply of Machinery (Safety) Regulations 2008 or the Plugs & Sockets (Safety) Regulations 1994.

Light Up Unicorn Wand - Recall

wand product recall

Risk

Chemical, choking and burns.

Details

A battery-operated blue light up unicorn wand.

The battery compartment on the products is not adequately secured, allowing easy access to the compartment and button cell batteries. The batteries may be placed in the mouth and swallowed, presenting a choking hazard for young children and causing damage to the gastrointestinal tract.

Additionally, the product included electrical components with solder joints, and when tested, the solder was found to contain lead at a concentration that exceeds the 0.1% maximum limit specified, which presents an environmental hazard.

The bag used for packaging poses a potential asphyxiation hazard to the intended consumer, and some of the required documentation was not present.

The product does not meet the requirements of the Toys (Safety) Regulations 2011, or the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (RoHS).

Portable Desktop Fan Heater Z14 - Safety Notice

heater safety notice

Risk

Fire

Models affected

Model: Z14
SKU: HTR-B19

Details

A small white and gold portable fan heater with black grill.

The product presents a serious risk of fire as, during testing, some of the internal wiring melted, resulting in an electrical short circuit. If the product was to short circuit during use, this could cause a current overload and overheating in the appliance, causing it to catch fire. Improvements are required to marking, labelling and documentation.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

Merkury Innovations, Lifestyle Advanced, Simplytech And Tech Theory Wireless Chargers - Recall

wireless charger recall

Risk

Burns

Models affected

Receipt codes: 472958, 472962, 472984, 475522, 488002, 490524, 506322, 506379, 512514, 525283 or 525489
Sales period: September 2023 to February 2024

Details

Four models of black wireless chargers.

All four products present a risk of burns as it has been identified that if a metal object is placed near the charger during use, the product can overheat which may cause it to melt or burn the skin if touched.

The products do not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

LAX, Gentek, Cleverworks And Brookstone Wireless Chargers - Recall

Risk

Burns

Models affected

Receipt codes: 485412, 485416, 489784, 504157, 504166 or 504156
Sales period: September 2023 to February 2024

Details

Four models of wireless charger, including white Brookstone standing wires charger, Gentex white circular wireless charger, LAX black wireless charger and Cleverworks pink circular wireless charger with a smiley face.

The products present a risk of burns as it has been identified that if a metal object is placed near the charger during use, the product can overheat which may cause it to melt or burn the skin if touched.

The products do not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

JUSFIT Lithium Electric Chain Saw, D-04 - Safety Notice

chainsaw safety report

Risk

Electric shock

Models affected

Brand: JUSFIT
Model: D-04
Charger model: YH-2105

Details

A black and dark green handheld chainsaw with replaceable battery packs and charging cable.

The product presents a serious risk of electric shock as it does not meet the dimensional requirements of BS 1363. Users may access live pins when plugging in, or unplugging, the plug from the socket. The product also presents a risk of electric shock as the transformer was of a poor build quality and did not meet the creepage and clearance requirements due to primary and secondary windings being found to be touching. Some of the required documentation and markings were not present.

The product does not meet the requirements of the Supply of Machinery (Safety) Regulations 2008 or the Plugs & Sockets (Safety) Regulations 1994.

JUSFIT Charging Drill, CDZ1820 - Safety Notice

Risk

Fire

Models affected

Brand: JUSFIT
Model: CDZ1820
Charger model: YH-2105
Other product identifiers: M010000000004674439, HG00070LHUK, WI34513457, B0400000001147361070, 910462231207071

Details

A black and green with a lithium battery power supply and black charging cable/plug. The product comes in a black carry case and was packaged in a brown cardboard box.

The product presents a serious risk of fire as the as the plug does not meet the dimensional requirements of BS 1363. As the plug does not make a proper connection with the socket, over extended use, the plug face could start to wear and result in the plug overheating. The product also presents a risk of electric shock as the transformer was of a poor build quality and did not meet the creepage and clearance requirements due to primary and secondary windings being found to be touching. Some of the required documentation and markings were not present.

The product does not meet the requirements of the Supply of Machinery (Safety) Regulations 2008 or the Plugs & Sockets (Safety) Regulations 1994.

2 Way Garage Consumer Unit 40A 30mA RCD 2MCB 6A+16A - Safety Notice

latest electrical product recalls

Risk

Fire

Models affected

Brand: SEG
ASIN: B09N6MST3Q

Details

A white 2-way garage consumer unit with red switches.

The product presents a serious risk of fire as the RBCO does not cut out as required. Under fault conditions, this could lead the RBCO to overheat and ignite, causing a fire.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

SEG 3 Way Garage Consumer Unit - Safety Notice

Risk

Fire

Models affected

Brand: SEG
ASIN: B08HRMNB2W

Details

A white, three-way consumer unit.

The product presents a serious risk of fire as the RBCO does not cut out as required. Under fault conditions, this could lead the RBCO to overheat and ignite, causing a fire.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

SEG 4 Way Garage Consumer Unit 63A 30mA RCD 4MCB 2 * 6A+20A+32A - Safety Notice

Risk

Fire

Models affected

Brand: SEG
ASIN: B08R3NK6WN

Details

A white, four-way consumer unit with red switches.

The product presents a serious risk of fire as the RBCO does not cut out as required. Under fault conditions, this could lead the RBCO to overheat and ignite, causing a fire.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

What to do next?

If you believe you have an affected product stop using it immediately and contact the retailer for further advice.

We strongly recommend that anyone who discovers they have an electrical item that has been recalled should stop using it until it has been checked by the manufacturer.